On-Line UPS AHA-373DX/503DX/603DX
Features
- Double conversion, IGBT module, true on-line isolated UPS
- Single control board design, for easy maintenance
- User friendly design and simple operation
- Unique avr built-in for super wide input voltage range
- Constant power, special overload capacity design
- Built-in high capacity battery charger for long backup time
- Special air-flow control, suitable for any dirty operation environment
- Front side operation design for easy installation and maintenance
- Very compact and light design easy to fit into any office corner
- Smart communication function support MAGATEC RUPSII UPS monitoring software
- The charger board is design by CCCV (Constant Current Constant Voltage) that could extend the battery life two times (3~6years) including the battery high voltage protection and O/P short circuit protection.
- MTBF (Mean Time Before Failure) > 80000hrs
- MTTR (Mean Time To Replacement) < 30 minutes
- CE Approved
- All models from 3.75K to 10KVA are used the same Main PCB. Customers only need to keep one bo
Overview
The Vesta series provides comprehensive protection and high power density in small and economic package. Compared to traditional UPS towers of the same size, Vesta UPS is more compact and offers greater comprehensive power protection against surges and spikes. Equipped with a voltage stabilizer, this UPS will continue providing clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability, perfect for any home or small office applicatio
|
Model |
AHA-373-DX |
AHA-503-DX |
AHA-603-DX |
Capacity |
3.75KVA / 3KW |
5KVA/4KW |
6KVA/4.8KW |
Input |
Voltage |
single phase 220Vac -20% +35% |
Frequency |
50Hz or 60Hz +/- 5% |
Output |
Voltage |
single phase 220Vac +/- 5% (adjustable) |
Frequency |
50Hz or 60Hz |
Voltage Regulation |
+/- 1% |
Frequency Stability |
+/- 0.5% (Free Running) |
Transient Response |
+/- 3% (100% load variation) |
Waveform |
Sinewave THD < 3% at 0-100% linear load |
Overload Capacity |
120% load 30 seconds, >150% constant power. |
Power factor |
0.7-1, lag |
Crest ratio |
3 : 1 |
Battery |
Voltage |
192Vdc |
Charger |
5A charger build in |
Efficiency |
AC to AC |
>85% |
Transfer Time |
AC Fault |
Zero |
Protection |
Battery |
Battery low shutdown and breaker |
Overload |
125% 30sec. switch to bypass line & automatic re-transfer |
Short Circuit |
Current Limited and cut-off and fuse and breaker |
UPS Fault |
Bypass, load supplied from mains less than 2ms. |
EMI/EMC |
EN50091-2, CE Approved |
Audible Alarm |
Mains Failure |
Sounding every four seconds after mains fail, 90 seconds mute |
Final Discharge |
Sounding once every second as battery approaches |
Overload |
Continuously |
UPS Fault |
Continuously |
Indicator |
LCD |
UPS state, I/P&O/P voltage, I/P&O/P frequency,
Battery voltage, Loading %, History record |
|
LED |
Utility LED (green), Inverter LED (green), Battery Low (yellow)
Bypass voltage (yellow) Fault LED (red), Overload (yellow) |
Interface |
Contact Closure |
Support MEGATEC RUPS UPS monitoring software |
RS-232 |
Support MEGATEC RUPSII / UPSilon 2000 monitoring software |
Environment |
Operation Temperature |
0-40 degree C; 32-104 degree F |
Relative Humidity |
20-90% non-condensing |
Audible Noise |
Less than 45dB(at 1 meter) |
Physical |
Net Weight (KGS/LBs) |
69kgs without battery |
Dimension (WxHxD)mm |
230 x 685 x 578 |
* Specifications are subjected to change without prior notice.
|
|